The bright digital tube displays clearly, allowing for clear readings whether used during the day or at night
Sensors can be easily replaced with 2P terminals, and when you need to use other probes, you can replace them freely
ABS material shell, delicate and beautiful, high mechanical strength, good electrical performance, anti-aging
-50~110 ℃ ultra wide temperature control range, can be used in various temperature control fields, with a temperature control accuracy of 0.1 ℃, meeting your control needs
Wiring input and output design, more convenient to use in various industrial control equipment, multi stranded wire 300V/20A overload configuration, safe and reliable
Product information:
Product Name: Microcomputer Temperature Controller
Product model: XH-W3002
Temperature measurement range: -50~110 ℃
Temperature control range: -50~110 ℃
Temperature measurement accuracy: ± 0.2 ℃
Temperature control accuracy: ± 0.1 ℃
Measurement input: NTC10K L=1 meter waterproof probe
Input power supply: 12/24/220V
Output power: 120/240/1500W
Output type: Direct output
Output capacity: maximum 10A
Installation hole spacing: 73mm (aperture 4mm)
External dimensions: 60 * 45 * 31mm
Set up using:
Code and function introduction
P0 set startup temperature
Press the setting button once to enter the internal menu, the default display is P0, press the setting button again, and set the required startup temperature by pressing the up and down buttons.
P1 set stop temperature
Press the setting button once to enter the internal menu, the digital display is P0, switch to P1 by pressing the up and down buttons, press the setting button again, and set the desired stop temperature by pressing the up and down buttons.
P2 Set temperature correction
Enter the internal menu in the same way, switch to P2 by pressing the up and down buttons, press the setting button again, and set the required calibration temperature by pressing the up and down buttons. In the setting, if the detected temperature value is 0.5°C higher than the actual temperature value, the calibration temperature to be set is -0.5°C. If the detected temperature value is 1°C lower than the actual temperature value, the calibration temperature to be set is 1°C. Detected temperature±corrected temperature=actual temperature.
P3 set delay start
Enter the internal menu in the same way, switch to P3 by pressing the up and down keys, press the setting key again, and set the required delay time (unit is minutes) by pressing the up and down keys. Delay start is generally used for compressor refrigeration. If it is used for refrigerator freezers, this value needs to be set. According to the size of the compressor back pressure, the general setting value is 3-6 minutes. If you are not used to control the compressor or do not need delay time function, skip this item directly.
Package includes:
Thermostat X1